Environmental data acquisition systems frequently connect multiple RS485 Modbus soil moisture, temperature, and electrical conductivity (EC/salinity) probes through individual USB-to-UART serial adapters. When Windows 11 recognises two sensors but refuses to detect or assign a COM port to the third device, USB composite endpoint exhaustion, COM port ID collisions, or selective suspend throttling are occurring.
Reassign Static COM Port Numbers in Device Manager
Multiple identical USB-to-serial bridge chips (such as FTDI, CP2102, or CH340) frequently contest the same virtual COM port index:
- Right-click the Start button and select Device Manager.
- Expand the Ports (COM & LPT) category.
- If the third sensor appears with a yellow exclamation mark or shares an existing COM number, double-click the device.
- Navigate to the Port Settings tab and click Advanced.
- Change the COM Port Number dropdown to an unassigned integer between COM10 and COM25.
- Click OK, disconnect the USB cable, wait five seconds, and reconnect.
Disable USB Selective Suspend and Power Saving
When multiple continuous serial streams operate simultaneously, aggressive Windows power management shuts down downstream ports:
- In Device Manager, expand Universal Serial Bus controllers.
- Right-click each USB Root Hub and Generic USB Hub, then select Properties.
- On the Power Management tab, uncheck Allow the computer to turn off this device to save power.
- Open Control Panel > Power Options > Change plan settings > Change advanced power settings.
- Expand USB settings > USB selective suspend setting, and configure both Battery and Plugged In states to Disabled.
Distribute Bus Load Across Independent Host Controllers
USB root hubs impose hardware endpoint limits that fail when multiple high-frequency Modbus RTU transceivers operate across passive unpowered splitters:
- Relocate the third sensor adapter from passive hubs directly into an independent rear motherboard USB port (or a dedicated PCIe USB expansion card).
- If using external hubs, ensure the unit utilizes an active mains-powered external power adapter capable of delivering continuous 5V 2A rail stability.
- Verify that Modbus slave addresses are unique across all physical probes (e.g. Slave ID 1, 2, and 3) before starting telemetry logging software.